M1400 Parallel Input /Output Beckhoff II/O-System
Date : 26.7.94 Version : 2.0 Page 9 of 16
The following modul configuration is possible by setting jumpers 4 to 7 :
Fast Inputs M1400 (Interrupt Inputs)
Jumper 4
Fast input II3 :
If jumper connection betwenn port D0.3 and XILINX II3 is
established Fast input is activated
Jumper 5
Fast input II2 :
If jumper connection betwenn port D0.2 and XILINX II3 is
established Fast input is activated
Jumper 6
Fast input II1 :
If jumper connection betwenn port D0.1 and XILINX II3 is
established Fast input is activated
Jumper 7
Fast input II0 :
If jumper connection betwenn port D0.0 and XILINX II3 is
established Fast input is activated
Power Supply
There are the following connections for power Supply :
(1) two pole plug connection for the controller (X10 Pin1+2)
(2) two pole plug connection for outputs (X20 and X30 Pin1+2)
( 16 outputs )
(3) two pole plug connection for inputs (X21 and X31 Pin1+2)
(16 inputs)
(4) two pole plug connection for ground (X22 and X32 Pin1+2)